EasyManua.ls Logo

Hyd-Mech DM8 - Electromagnetic Compatibility; Emissions

Hyd-Mech DM8
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 24DM
Safety and accident prevention 3--9
Electromagnetic compatibility
As from 1 January 1996 all electrical and electronic appliances bearing the CE
marking that are sold on the European market must conform to Directive
89/336/EEC and decree law no. 476/92 concerning electromagnetic compatibility,
i.e. the compatibility of electrical/electronic devices and systems with the
electromagnetic environment in which they are located. The prescriptions regard
two specific aspects in particular:
1. “EMISSIONS: during its operation, the appliance or system must not emit spurious
electromagnetic signals of such magnitude as to contaminate the surrounding
electromagnetic environment beyond clearly prescribed limits”;
2. “IMMUNITY: the appliance or system must be able to operate correctly even when
it is placed in an electromagnetic environment that is contaminated by disturbances
of defined magnitude”.
The following text contains a list of the applied standards and the results of the
electromagnetic compatibility testing of machine model DM 8;
Test report no. 061200.
Emissions
= EN 50081--2 (1994) Electromagnetic Compatibility -- Generic standard regarding
emissions. Part 2: Industrial Environment.
= EN 55011 (1999) Industrial, scientific, and medical radio frequency appliances
(ISM). Characteristics of radio frequency disturbance -- Limits and methods of
measurement.
= EN 55014--1 + A2 (1998 --1999) Electromagnetic Compatibility -- Prescriptions for
domestic appliances, electric power tools, and similar equipment. Part 1: Standard
Emission in relation to product family.
CONDUCTED EMISSIONS
Gate A Freq. (MHz) Q --- p e a k l i m i t ( d B u V ) Mean value limit (dBuV) Result
A.C. mains 0.15 --- 0.5
0 . 5 --- 5
5 --- 3 0
66---56
(linear reduction with
log of frequency)
56
60
56---46
(linear reduction with log of fre-
quency)
46
50
COMPLIES
CONDUCTED EMISSIONS --- ANALYSIS OF INTERMITTENT DISTURBANCES
Gate Result
A.C. mains Not applicable
IRRADIATED EMISSIONS
Gate Limit (class) Result
A.C. mains A Complies

Table of Contents