R
Rita RushDec 1, 2025
Why won't the pump on my HydraMaster CTS 403 Flex Cleaning Equipment reach normal cleaning pressure?
- CCarl ParrishDec 1, 2025
If the pump on your HydraMaster Cleaning Equipment won't reach normal cleaning pressure, the tile pressure adjusting valve may be faulty, so inspect the valve and repair or replace if necessary. Worn seals or valves in the tile pump can also cause this, so test the pump output volume directly from the pump at normal running rpm; if the volume is below the manufacturer’s specifications, replace the seals and inspect for defective valves. The pump rpm may be too low, so check for a loose pump belt and adjust or replace as necessary. Check the engine rpm and adjust as necessary to 3,150 rpm under a 0” Hg vacuum load. The tile primary orifice may be missing or loose, so remove and inspect, tightening or replacing as necessary. The tile primary and secondary orifices may have been installed inc...



