Troubleshooting: 7-2
HEATING SYSTEM
1.0 Truckmount overheats and shuts down
Possible Cause Solution
1.1 The tile orice or lter
screen are restricted.
Remove and inspect. Clean as necessary.
1.2 The tile dump solenoid is
restricted.
Inspect the solenoid and the hose that delivers
water to it. Clean or replace as necessary.
1.3 The tile dump solenoid is
faulty.
Check the main fuse. If the fuse is blown, inspect
electrical system for worn or shorted wires. Repair
or replace as necessary.
Inspect the solenoid and test for functionality. If the
solenoid is operable, refer to a qualied service
technician to test the temperature controller and
sensor.
2.0 Unable to achieve normal cleaning solution temperature
Possible Cause Solution
2.1 Tile temperature control
knob is turned down.
Inspect the knob. Adjust if necessary.
2.2 The tile dump solenoid is
faulty.
Inspect the solenoid and test for functionality. If the
solenoid is operable, refer to a qualied service
technician to test the temperature controller and
sensor.
2.3 Excessive solution ow at
tool.
The cleaning tool jet is too large or worn. Inspect the
jet. Replace if necessary.
2.4 The heat exchanger has
hard water scale buildup.
Descale the system.
2.5 The heat exchanger has
blockage on the exhaust
side.
Inspect the interior of heat exchanger. Remove the
debris and clean as necessary.