4-11: Machine Maintenance
DESCALING PROCEDURE - CARPET/UPHOLSTERY
1. Connect a solution hose to the Carpet/Uph. Cleaning Solution Outlet.
2. Route the other end of the solution hose to the Flex tank.
3. Attach an open quick connect to the other end of the hose.
The descaler will drain from the female QC tting assembly/hose quickly. Have
extra buckets ready to swap out because each bucket should ll quickly.
4. Pour 5 gallons of descaler solution into each of the Flex tanks.
5. Turn the ignition switch to the “ON” position.
6. Select “CARPET/UPH.” on the Solution Control switch.
7. Add water to the Flex tank to ush all descaler out of the solution line.
8. Select “OFF” on the Solution Control switch.