4-3: Machine Maintenance
250 Hours
Check coupler (rubber sleeve) for cracks or wear. Replace as necessary.
500 Hours
Change the blower oil.
Change the high pressure pump oil.
Check the engine valve clearance (intake and exhaust 0.004” - 0.006”)
Change the fuel lter.
Check coupler (rubber sleeve) for cracks or wear. Replace as necessary (Coupler
Sleeve Part Number: 000-152-015).
1000 Hours
Change air lters.
Check carburetor. Clean or replace as necessary.
Clean the heat exchanger core.
Check coupler (rubber sleeve) for cracks or wear. Replace as necessary (Coupler
Sleeve Part Number: 000-152-015).
Refer to the Interval Hours Maintenance chart in the Owner’s Guide.