Preventive maintenance
4
128 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
After a symbol is selected, the Maintenance Reason screen opens.
1
2
3
4
1 DynaMAX premium high-pressure seal
repair kit (500 hours)
2 Check valve assembly (1,500 hours)
3 1-12084 DynaMAX 5-series standard
Tool kit (1,000 hours)
4 Low-pressure poppet basket
(1,500 hours)
5
6
7
5 High-pressure cylinder (3,000 hours)
6 Indicator pin spring (3,000 hours)
7 Plunger bearing (3,000 hours)
8
9
10
11
8 Indicator pin (6,000 hours)
9 Output adapter (6,000 hours)
10 Seal housing (6,000 hours)
11 Spacer tube (12,000 hours)