EasyManuals Logo

Hypertherm DynaMAX 550P User Manual

Hypertherm DynaMAX 550P
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #160 background imageLoading...
Page #160 background image
Troubleshooting
6
160 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
No Is the output temperature hot?
Yes Inspect the high-pressure poppet.
No Inspect the low-pressure poppet.
Examine the low-pressure poppet and the
check valve body.
Make sure that the mating surfaces are clean
and smooth with a mirror like finish.
Repair or replace the low-pressure poppet.
Repair or replace the poppet retainer.
Make sure that the low-pressure poppet fits
in the poppet retainer without sticking. Shake
the assembly and listen for the poppet
moving inside.
Is the overstroke is to the left? A poppet is sticking, worn, or damaged.
Check the low-pressure poppet on the left
side of the intensifier.
Check the high-pressure poppet on the right
side of the intensifier.
Is the overstroke is to the right? A poppet is sticking, worn, or damaged.
Check the low-pressure poppet on the right
side of the intensifier.
Check the high-pressure poppet on the left
side of the intensifier.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm DynaMAX 550P and is the answer not in the manual?

Hypertherm DynaMAX 550P Specifications

General IconGeneral
BrandHypertherm
ModelDynaMAX 550P
CategoryWater Pump
LanguageEnglish

Related product manuals