Troubleshooting
6
160 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
No Is the output temperature hot?
Yes Inspect the high-pressure poppet.
No Inspect the low-pressure poppet.
Examine the low-pressure poppet and the
check valve body.
Make sure that the mating surfaces are clean
and smooth with a mirror like finish.
Repair or replace the low-pressure poppet.
Repair or replace the poppet retainer.
Make sure that the low-pressure poppet fits
in the poppet retainer without sticking. Shake
the assembly and listen for the poppet
moving inside.
Is the overstroke is to the left? A poppet is sticking, worn, or damaged.
Check the low-pressure poppet on the left
side of the intensifier.
Check the high-pressure poppet on the right
side of the intensifier.
Is the overstroke is to the right? A poppet is sticking, worn, or damaged.
Check the low-pressure poppet on the right
side of the intensifier.
Check the high-pressure poppet on the left
side of the intensifier.