Specifications
7
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 183
Steel JIC 37°
SAE O-ring boss
Lubricate the threads of steel JIC fittings with hydraulic fluid.
This table shows maximum values. The torque necessary to make a sufficient seal
depends on the condition of the pipe threads and can be much lower than the
maximum.
1/16-inch
dash size
Minimum Maximum
Nm lbfft Nm lbfft
-04 14 10 15 11
-06 23 17 26 19
-08 46 34 52 38
-10 68 50 76 56
-12 95 70 10 6 78
-16 127 94 141 104
-20 168 124 187 138
-24 212 156 235 173
Do not use thread sealant on SAE hydraulic fittings.
Lubricate O-rings with hydraulic fluid or O-ring lubricant before assembly.