Installation
8
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 209
Start Procedure Timers
All time is in seconds.
Ramp Time This is the time that the system takes to increase the high-pressure water pressure
from0 to the target water pressure.
Increase the value to slow the process.
The timer default is between3 seconds and8seconds, based on the pump model.
The value cannot be lower than the default.
Intensifier The system goes to the next stage when the time between intensifier strokes is this value.
The timer default is1.5 seconds.
Inlet Water Stage 1
After the system gets to the minimum water manifold pressure, the inlet water timer
starts.
The timer default is5 seconds.
Bleed Valve Stage 2
This is the time it takes for the intensifier to push air in the system out through the
bleed-down valve.
The timer default is5 seconds.
Hydraulics Stage 3
After the bleed-down valve closes, the system has this much time to get to the minimum
hydraulic pressure.
The timer default is5 seconds.
The hydraulic pressure setpoint default is17bar(250psi).
Pierce Stage 4
The system has this much time to get to the pierce-pressure setpoint.
The timer default is5 seconds.
Cut Stage 5
If the pump is in cut-pressure mode, the system has this much time to get to the
cut-pressure setpoint.
The timer default is5 seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm DynaMAX 550P and is the answer not in the manual?

Hypertherm DynaMAX 550P Specifications

General IconGeneral
BrandHypertherm
ModelDynaMAX 550P
CategoryWater Pump
LanguageEnglish

Related product manuals