Installation
210 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Pressure Adjustments
Maximum This is the maximum pressure that the system can be adjusted to.
The default is4,140bar(60,000psi).
Increments
Increase This is how much that the target pressure increases each time the + symbol on the
primary operation screen is touched.
The default is 34 bar (500 psi).
The smallest increment is10bar(100psi).
Decrease This is how much that the target pressure decreases each time the – symbol on
the primary operation screen is touched.
The default is34bar(500psi).