210 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Pressure Adjustments
Maximum This is the maximum pressure that the system can be adjusted to.
The default is4,140bar(60,000psi).
Increments
Increase This is how much that the target pressure increases each time the + symbol on the
primary operation screen is touched.
The default is 34 bar (500 psi).
The smallest increment is10bar(100psi).
Decrease This is how much that the target pressure decreases each time the symbol on
the primary operation screen is touched.
The default is34bar(500psi).