Operation
42 810770 Operator Manual Echion
3. Clean all debris, water, and hydraulic fluid off of the hydraulic fluid tank , the intensifier
bridge , and the bottom deck .
4. Empty the dirty water container , if necessary.
5. Clean the operator interface, if necessary.
Gently wipe the touchscreen and keys with a clean microfiber cloth.
Use a cleaner made for touchscreens or use a1:1 solution of distilled water and white
vinegar.
6. Examine electrical cords and cables for kinks or damage to the insulation. Examine electrical
plugs and other electrical connections for corrosion or damage.
7. Look for leaks, deterioration, damage, or other conditions that can interfere with operation.
8. Make sure that all connections, fasteners, locking devices, hoses, and fittings are tight.
9. Make sure that all warning decals are visible and legible.
Contact Hypertherm for replacement decals.
Refer to local regulations regarding waste water. Environmental rules can apply to
disposal.
To prevent damage to the operator interface:
do not use cleaners that contain alcohol, ammonia, acetone, phosphates, or
ethylene glycol.
do not push hard on the touchscreen.
do not use paper towels, abrasive cloth, or dirty rags.
do not put liquid directly onto the touchscreen.