Preventive maintenance
3
Echion Operator Manual 810770 63
Preventive maintenance
Parts, tools, and materials
Refer to Intensifier high-pressure ends on page 107 for individual replacement parts.
Do this task when the pump is not operating.
1. On the operator interface, touch the maintenance symbol to open the primary maintenance
screen.
2. Touch this symbol to open the Move the Plunger screen.
3. Touch the motor symbol to start the motor.
Intensifier repair tools
1-18770 Echion high-pressure seal repair kit
1-18771 Echion high-pressure poppet repair kit
1-18849 Echion low-pressure poppet repair kit
1-18768 Standard tool kit
13/16-inch open-ended wrench or socket
1-inch open-ended wrench
1-1/16-inch open-ended wrench
1-inch socket
Torque wrench
Rubber mallet
2 O-ring picks (or similar tool)
2 standard screwdrivers
Large snap-ring pliers
Small snap-ring pliers
Isopropyl alcohol
Antiwear (AW) mineral oil or synthetic hydraulic
fluid, ISO viscosity grade (VG) 32 or 46
Clean towels
Nonstick scouring pad
Masking tape
Recommended materials
Bench vise