Preventive maintenance
Echion Operator Manual 810770 95
14. Install the water filter canister with the filter.
15. Do this procedure for a water-cooled system.
a. Use a 1-inch open-ended wrench to connect the compressed air hose to the Cooling in
connection.
The Cooling in connection is 1/2-inch NPT female. An adapter (not included) is
necessary.
b. Use a 1-3/16-inch open-ended wrench to disconnect the Cooling out line from the pump.
c. Disconnect the compressed air hose from the Cooling in connection.
d. Do step 8 through step 12 again.
16. Install the original caps and the plugs for the utility connections.
Air-cooled systems do not require fluid removal.