Wiring
Table
of
Contents
EC connection unit /
Drive cutoff connector
Items to prepare
RCON system
Wiring for EC Connection Unit Drive Cutoff Circuit
6
Connection the Drive Cutoff Connector
Although the EC connection unit is supplied the 24V power from the RCON
gateway unit, the circuit related to drive cutoff is equipped in the EC connection
unit side.
When externally shutting off the motor drive source to comply with the safety
category or the like, connect a contact such as a relay to the wiring between
the MPI* and MPO* terminals.
Use wires with diameter large enough for allowable current higher than the
current actually used.
Smaller diameter of the cables than applicable could cause abnormal high heat
when flowing current. This could melt the coating on cables and set a fire.
Insert connector
firmly till end
Drive Cutoff Connector
(Model: DFMC1.5/4-ST-3.5)
EC Connection Unit
(Model: RCON-EC-4)