The 200V driver unit is equipped with a drive cutoff circuit and a driver stop circuit
(DRV STOP) by internal semiconductor instead of an external drive cutoff connector.
The driver stop circuit (DRV STOP) cuts off the energy supply to a motor by the
cutoff circuit inside the controller after the reaction time (8ms or less) has passed in
accordance with an input signal.
When a driver stop feature is to be used,
it is necessary to use the I/O wiring.
When Cable to be Used (Sold separately)
Model Code: CB-SC-STO***
When Cable Not to be Used
It is necessary to prepare a connector
and create a cable.
Manufacture: Tyco Electronics
Model Code : 2013595-1 (Soldering type)
*There is cold-welding type also available.
*It is necessary to have a cramping tool
2229737-1.
Connect the dummy plug (DP-6)
enclosed to RCON-SC-1.
not used
Driver
Stop Circuit
used
*Check RCON Instruction Manual (ME0384)
for details.
Dummy Plug (DP-6)
RCON system
Dummy Plug
(Model: DP-6)
Insert until
it clicks
Driver Stop Connector
200V Driver Unit
(Model: RCON-SC-1)
About RCON-SC “DRV STOP”