EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
142
Part 2 Programs
PPUT (Write position data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional PPUT
Axis
number
Position
number
CP
[Function] Write the value in variable 199 to the axis number specified in operand 1 in the position data
specified in operand 2.
[Example 1] LET 199 150 Assign 150 to variable 199.
PPUT
2 3 Write the content of variable 199 (150) to axis 2 at position
3.
[Example 2] LET 199 150 Assign 150 to variable 199.
LET 1 2 Assign 2 to variable 1.
LET 2 3 Assign 3 to variable 2
PPUT *1 *2 Write the content of variable 199 (150) to the content of
variable 1 (axis 2) at the content of variable 2 (position 3).