EasyManua.ls Logo

IAI ssel - Page 176

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
Part 2 Programs
PDCL (Assign deceleration data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional PDCL Deceleration
Position
number
CP
[Function] Assign the deceleration data specified in operand 1 to the deceleration item in the position
data specified in operand 2.
The deceleration is set in G and may include up to two decimal places.
[Example 1] PDCL 0.3 3 Assign 0.3 to the deceleration data at position No. 3.

Table of Contents

Other manuals for IAI ssel

Related product manuals