EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
158
Part 2 Programs
ACC (Set acceleration)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional ACC Acceleration Prohibited CP
[Function] Set the travel acceleration of the actuator.
The maximum acceleration will vary depending on the load and model of the actuator
connected.
The acceleration is set in G and may include up to two decimal places.
(Note) If the position data contains no acceleration AND acceleration is not set by an ACC
command, the actuator will move based on the default value set in “All-axis parameter No.
11, Default acceleration.”
[Example 1] ACC 0.3 Set the acceleration to 0.3 G.
(Note) Setting an acceleration exceeding the specified range for the actuator may generate an error.
It may also result in a failure or shorter product life.

Table of Contents

Other manuals for IAI ssel

Related product manuals