EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
255
Part 2 Programs
B. Method to set palletizing positions in parallel with the actuators
Palletizing reference point: Store the position data of the start point (palletizing position No. 1) in a
position data field and specify the applicable position number using a
PAST command, as shown below.
Palletizing pitches: Use a PAPT command to specify the pitches in the PX-axis and PY-axis
directions.
Palletizing axes: Use a PASE command to specify the two axes, one representing the
PX-axis direction and the other representing the PY-axis direction, to be
used in palletizing.
(An actuator axis number parallel with the preferential axis (PX-axis) and another perpendicular to the
preferential axis)
PAST 100 Teach position data No. 100 as the start point.
PAPT 45 30 The PX-axis direction pitch is 45 mm and the PY-axis direction
pitch is 30 mm.
PASE 2 1 See two axes for PX-axis and one axis for PY-axis.
(Note) When the above palletizing axes, palletizing pitches and palletizing reference point
are used, the PX-axis and PY-axis must be parallel with the actuators and crossing
with each other.
Select either method A or B for each palletizing setting.
A
xis 2
PX-axis direction pitch
45
30
Teach position data No. 100.
Axis 1
PY-axis direction pitch

Table of Contents