269
Part 2 Programs
(3) SSEL Controller application program
Step E N Cnd Cmnd Operand 1 Operand 2 Pst Comment
1 HOME 11 XY-table returns to home (servo ON).
2 VEL 400 Set speed to 400 mm/s.
3 TAG 1
4 MOVL 1 Move to position No. 1 (work home).
5 LET 1 2 Set 2 in load counter.
6 BTOF 600 Clear completion flag.
7 WTON 16 Wait for start command.
8 TAG 2
9 MOVL *1 Move to load counter position.
10 BTON 307 Riveting command turns ON.
11 WTON 17 Wait for riveting to complete.
12 BTOF 307 Riveting command turns OFF.
13 ADD 1 1 Increment load counter by 1.
14 CPEQ 1 5 600 Turns ON flag if operation is complete.
15 N 600 GOTO 2 Jump to TAG2 if not complete.
16 GOTO 1 Jump to TAG1 if complete.