EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
377
Appendix
Input function specification value 9: Start-program number specification bit 1 (least significant bit)
This bit specifies the least significant bit of a program number.
Note: Start-program number specification bits x (input function
setting values 9 through 15) cannot be assigned
discontinuously from the least significant bit or in
descending order from the least significant bit.
Input function specification value 10: Start-program number specification bit 2
This bit specifies the second bit of a program number.
Input function specification value 11: Start-program number specification bit 3
This bit specifies the third bit of a program number.
Input function specification value 12: Start-program number specification bit 4
This bit specifies the forth bit of a program number.
Input function specification value 13: Start-program number specification bit 5
This bit specifies the fifth bit of a program number.
Input function specification value 14: Start-program number specification bit 6
This bit specifies the sixth bit of a program number.
Input function specification value 15: Start-program number specification bit 7
This bit specifies the seventh bit of a program number.
Input function specification value 16: Error reset (ON edge)
This signal is used to reset errors.
Note: Only errors of operation-cancellation level or lower can be
reset using this signal.
Input function specification value 17: Drive-source cutoff reset input (ON edge) (Effective when the
problem factor has been removed)
This signal is used as a drive-source cutoff reset input when the
emergency stop/enable switch recovery type is set to “Operation
continued.”
Input function specification value 18: Home-return command signal for all valid axes (ON edge)
This signal commands home return of all valid axes.
Note: The servo ON input signal (input function specification
value 4) must be turned ON first.
Input function specification value 19: Home-return command signal for all incremental axes (ON edge)
This signal commands home return of all incremental axes.
Note: The servo ON input signal (input function specification
value 4) must be turned ON first.
Input function specification value 20: PC/TP-servo movement command acceptance permission input
Movements can be permitted from the PC software or teaching
pendant.
Input function specification value 21: Remote-mode control input
This signal can be used to switch between the AUTO mode and
MANUAL mode.
Note: Switching is enabled only when the mode switch is set to
“AUTO.”