EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
384
Appendix
Set a home preset
Axis-specific parameter No. 12, “Home preset value”
No. Parameter name Default value Input range Unit
12 Home preset value 0 -99999999 ~ 99999999 0.001 mm
Explanation of setting
Set a value indicating where the actuator should be upon completing home return.
(Normally, the actuator should be at 0-mm coordinate upon completing home return.)
Setting value
Unit: 0.001 mm
Example 1: “Do not set” a home preset value
Home return complete [0.000] mm is displayed.
Example 2: Set “3000” as a home preset value
Home return complete [3.000] mm is displayed.
Note
Take note that when a home-return preset value is set, the effective stroke will also change. In
particular, the stroke will decrease if the preset position is on the positive side of the default home.