EasyManua.ls Logo

IAI ssel - Page 412

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
386
Appendix
Apply length measurement correction
Axis-specific parameter No. 44, “Length measurement correction”
No. Parameter name Default value Input range Unit
44 Length measurement correction 0 -99999999 ~ 99999999 0.001 mm/1 M
Explanation of setting
Adjust the difference between the actual distance traveled and the measured distance, for the
commanded travel distance.
Example: Move the actuator from 0 mm to 1000 mm by specifying a position.
Correct the travel distance of [2] with respect to [1].
In the above example, enter “1000” because the actual distance traveled is 999 mm.
(Setting unit: 0.001/1 m)
* C10-class ball screws are subject to a margin of error of 0.21 mm per 300 mm.
[1] Absolute value (measured distance): 1000 mm
[2] Actual distance traveled (999 mm)

Table of Contents

Other manuals for IAI ssel