EasyManua.ls Logo

IAI ssel

IAI ssel
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
408
Appendix
Parameters Common to All Axes
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
25 (Acceleration/deceler
ation at home return
(old))
30 1 ~ 300 0.01 G (Invalid)
26 Acceleration/decelera
tion specification type
0 Reference
only
0: T system, 1: P, M system
27 Master axis type 0 Reference
only
0: T system, 1: P system
28 Selection of inching
jog auto-switching
prohibition
0 Reference
only
0: Execute auto-switching (Continuous button ON timer), 1:
Prohibited
* Referenced by the PC/TP (no handy terminal auto-switching
function)
29 All-axis setting bit
pattern 1
10000H 0H ~
FFFFFFFFH
Bits 0 to 3: Selection of use of last PC/TP inching distance (0:
Do not use, 1: Use)
* Referenced by the PC/TP
(Excluding ANSI-compatible TP)
Bits 4 to 7: Overrun (servo) error level (0: Operation-
cancellation level, 1: Cold-start level, 2: Operation-
cancellation level at reset, thereafter cold-start
level)
Bits 8 to 11: “Actual-position soft limit over (servo)” error level (0:
Operation-cancellation level, 1: Cold-start level, 2:
Operation-cancellation level at reset, thereafter
cold-start level)
Bits 12 to 15: For future expansion
Bits 16 to 19: Absolute-data backup battery voltage error level
(0: Operation-cancellation level, 1: Message level)
30 Default division angle 150 0 ~ 1200 0.1
degree
31 Default division
distance
0 0 ~ 10000 mm
32 Arch-trigger start-
point check type
0 0 ~ 5 0: Check operation amount and actual position, 1: Check
operation amount only
33 Safety speed in
manual mode
250 1 ~ 250 mm/s * This parameter is treated as a value equivalent to or below the
minimum value set in “Axis-specific parameter No. 29, VLMX
speed” for all valid axes.
34 ~
100
(For expansion) 0 ~
~
101 For future expansion 0H 0H ~
FFFFFFFFH
102 For future expansion 0H 0H ~
FFFFFFFFH
103 For future expansion 0H 0H ~
FFFFFFFFH
104 For future expansion 0H 0H ~
FFFFFFFFH
105 ~
120
(For expansion) 0 ~
~
~

Table of Contents