Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E139
Create
node
aliases
and
system
aliases
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E13A
Create
packages
node
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E140
Operating
system
load
See
“Boot
Problems/Concerns”
on
page
155.
E145
Early
debug
code
activated;
firmware
is
halted
Press
the
g
key
on
the
serial
interface.
E149
Create
boot
mgr
node
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E14C
Create
terminal-emulator
node
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E14D
Loading
boot
image
See
“Boot
Problems/Concerns”
on
page
155.
E150
Create
host
(primary)
PCI
controller
node
If
a
location
code
is
specified,
replace
the
adapter
at
that
location
code.
If
no
location
code
is
specified,
go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E151
Probing
primary
PCI
bus
If
a
location
code
is
specified,
replace
the
adapter
at
that
location
code.
If
replacing
the
adapter
does
not
resolve
the
problem,
replace
the
I/O
backplane
in
which
the
adapter
is
plugged.
If
no
location
code
is
specified,
go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E152
Probing
for
adapter
FCODE,
evaluate
if
present
Follow
the
repair
action
listed
for
checkpoint
E151.
E153
End
adapter
FCODE,
probe/evaluate
Follow
the
repair
action
listed
for
checkpoint
E151.
E154
Create
PCI
bridge
node
Follow
the
repair
action
listed
for
checkpoint
E151.
E155
Probing
PCI
bridge
secondary
bus
Follow
the
repair
action
listed
for
checkpoint
E151.
E156
Create
PCI
Ethernet
node
If
a
location
code
is
specified,
replace
the
adapter
at
that
location
code.
If
no
location
code
is
specified,
go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E158
System
firmware
waiting
for
a
virtual
terminal
to
be
opened
on
an
HMC
for
SMS
menus
to
be
displayed.
Open
a
virtual
terminal
window
on
the
HMC.
E15B
Transferring
control
to
operating
system
(service
mode
boot)
See
“Boot
Problems/Concerns”
on
page
155.
E15F
Adapter
VPD
probe
Follow
the
repair
action
listed
for
checkpoint
E151.
Chapter
4.
Checkpoints
141

Table of Contents