1011
2600
Pgood
fault
-
power
supply
domain
good
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
1011
2603
Pgood
fault
-
power
supply
domain
bad
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
1011
2612
Optical
converter
fault
System
backplane
Location:
U0.1-P1
1011
2630
1.2v
VRM
fault
VRM
module
Location:
U0.1-P1-V3
1011
2631
1.5v
VRM
fault
System
backplane
Location:
U0.1-P1
1011
2632
1.8v
VRM
fault
VRM
module
Location:
U0.1-P1-V1
1011
2633
2.5v
VRM
fault
VRM
module
Location:
U0.1-P1-V2
1011
3100
I2C
controller
fault
System
backplane
Location:
U0.1-P1
1011
3104
I2C
bus
4
fault
DASD
backplane
Location:
U0.1-P2
DASD
backplane
Location:
U0.1-P3
Media
backplane
Location:
U0.1-P4
Service
processor
Location:
U0.1-P1-X1
System
backplane
Location:
U0.1-P1
1011
3105
I2C
interface
fault
System
backplane
Location:
U0.1-P1
1011
3106
I2C
interface
fault
System
backplane
Location:
U0.1-P1
1011
3114
I2C
interface
fault
System
backplane
Location:
U0.1-P1
1011
3116
I2C
interface
fault
System
backplane
Location:
U0.1-P1
1011
3118
SPCN
VPD
collection
fault
System
backplane
Location:
U0.1-P1
1011
3119
DASD
backplane
fault
DASD
backplane
Location:
U0.1-P2
1011
311A
DASD
backplane
fault
DASD
backplane
Location:
U0.1-P3
1011
311B
Media
backplane
fault
Media
backplane
Location:
U0.1-P4
1011
7610
System
fan
1
fault
Fan
1
Location:
U0.1-F1
1011
7611
System
fan
1
missing
Fan
1
Location:
U0.1-F1
1011
7616
Power
supply
2
fan
missing
System
drawer
power
supply
2
Location:
U0.1-V2