5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
Memory
Error
Notes
Use
the
location
code
obtained
from
the
SMS
Error
Log
utility
(described
in
“Error
Log
Utility
Procedure”
on
page
200)
to
identify
which
memory
DIMM
(or
memory
DIMM
quad)
the
error
is
reported
against.
Memory
error
codes
are
in
the
form
25Cyyxxx
where
yy
indicates
memory
DIMM
present
detect-bits
(PD-bits)
and
xxx
indicates
the
last
3
digits
of
the
error
code.
See
“Memory
DIMM
Present
Detect
Bits
(PD-Bits)”
on
page
199
for
information
on
how
to
interpret
PD
bits.
25B0
0001
No
memory
DIMMs
detected.
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
25B0
0004
Multiple
memory
DIMMs
failed
a
memory
test.
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
25Cy
y001
DIMM
is
not
supported
Replace
unsupported
DIMM(s).
Note:
Memory
DIMMs
must
be
replace
with
a
supported
type
of
memory
DIMM.
If
an
unsupported
type
of
memory
DIMM
is
replaced
with
the
same
unsupported
type,
the
error
persists.
See
the
Memory
Error
Notes
on
page
184
for
more
information.
25Cy
y002
Memory
DIMM
fails
memory
test.
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
2602
0001
Description:
Invalid
PCI
adapter
vendor
ID
Action:
1.
Move
adapter
to
another
slot
(behind
a
different
PCI
bus).
2.
Check
for
available
firmware
updates
for
adapter.
Apply
update
if
available.
3.
Run
AIX
diagnostics
on
adapter.
Replace
if
indicated.
4.
Replace
adapter.
5.
Check
for
system
firmware
updates.
Apply
if
update
available.
6.
Replace
the
CEC
backplane,
location
U0.1-P1.
2602
0002
Description:
Invalid
PCI
adapter
device
ID
Action:
1.
Move
adapter
to
another
slot
(behind
a
different
PCI
bus).
2.
Check
for
available
firmware
updates
for
adapter.
Apply
update
if
available.
3.
Run
AIX
diagnostics
on
adapter.
Replace
if
indicated.
4.
Replace
adapter.
5.
Check
for
system
firmware
updates.
Apply
if
update
available.
6.
Replace
the
CEC
backplane,
location