6.
Service
Processor
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
450x
271B
System
backplane
with
1
processor
fault
Replace
the
CEC
backplane
Location:
U0.1-P1
450x
271C
System
backplane
with
2
processors
fault
Replace
the
CEC
backplane
Location:
U0.1-P1
450x
30D1
256
MB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D2
512
MB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D3
1
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D4
1
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
450x
30D5
2
GB
DIMM
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
69.
460x
26F4
System
backplane
with
1
processor
Replace
the
system
backplane,
Location:
U0.1-P1
460x
26F5
System
backplane
with
2
processors
Replace
the
system
backplane,
Location:
U0.1-P1
460x
271B
System
backplane
with
1
processor
Replace
the
system
backplane,
Location:
U0.1-P1
460x
271C
System
backplane
with
2
processors
Replace
the
system
backplane,
Location:
U0.1-P1
460x
28D0
Service
processor
Replace
the
service
processor,
Location:
U0.1-P1-X1
4B23
26F5
Description:
2-way
processor
card
fault
Action:
This
error
code
indicates
that
the
processor
repeat
gard
function
has
deconfigured
a
processor.
Do
the
following:
1.
Go
to
the
processor
configuration/deconfiguration
menu,
located
under
the
system
information
menu
in
the
service
processor
menus.
Look
at
the
status
of
the
processors.
If
any
of
the
processors
have
a
status
of
manually
deconfigured,
reconfigure
the
processor(s)
and
boot
the
system
to
the
SMS
menus.
Power
off
the
system
using
the
white
power
button
and
look
again
at
the
status
of
the
processors.
If
all
of
the
processors
are
still
configured
in
the
processor
configuration/deconfiguration
menu,
the
problem
has
been
resolved.
If
any
of
the
processors
have
a
status
of
deconfigured
by
the
system,
either
before
or
after
the
boot
to
the
SMS
menus,
go
to
step
2.
2.
Replace
the
processor
card
(on
which
the
deconfigured
processor
resides)
specified
by
the
location
code.
198
EserverpSeries
615
Service
Guide