Step
1240-6
Note:
If
only
one
quad
of
DIMMs
is
on
the
system
planar,
you
must
have
at
least
one
replacement
DIMM
of
the
same
size
and
speed
as
the
DIMMs
that
are
on
the
system
planar.
If
there
were
two
quads
of
DIMMs
on
the
system
planar,
but
they
are
not
the
same
size,
you
must
have
at
least
one
replacement
DIMM
of
the
same
size
and
speed
as
the
DIMMs
in
the
quad
that
is
failing.
If
there
were
two
quads
of
DIMMs
on
the
system
planar,
and
they
are
the
same
size
and
speed,
DIMMs
from
the
good
quad
can
be
used
when
isolating
the
failing
DIMM
in
the
suspect
quad.
1.
Turn
off
the
power.
Remove
the
power
cord.
2.
Remove
one
of
the
DIMMs
on
the
system
planar,
and
install
the
replacement
DIMM
or
another
DIMM
that
is
known
to
be
good.
3.
Reattach
the
power
cord.
Wait
for
OK
in
the
operator
panel.
4.
Turn
on
the
power.
Attempt
to
boot
to
the
SMS
menus.
(The
system
may
stop
with
an
8-digit
error
code
before
it
reaches
the
SMS
menus.)
5.
Power
down
the
system
using
the
white
button.
After
the
OK
appears
in
the
operator
panel,
look
at
the
memory
configuration/deconfiguration
menu.
Are
any
DIMMs
deconfigured
or
does
the
error
code
recorded
in
“Step
1240-1”
on
page
70
still
appear?
NO
The
DIMM
that
was
just
removed
was
the
failing
DIMM;
replace
it.
Enable
memory
repeat
gard
if
necessary.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Go
to
“Step
1240-7.”
Step
1240-7
Have
all
the
DIMMs
in
the
quad
located
on
the
system
planar
been
replaced?
NO
Go
to
“Step
1240-6”
to
test
the
next
DIMM
of
the
quad
on
the
system
planar.
YES
Go
to
“Step
1240-8.”
Step
1240-8
Did
the
processor
originally
have
only
one
quad
of
DIMMs
at
the
start
of
this
map?
NO
Call
support.
YES
Replace
the
system
planar.
This
ends
the
procedure.
Enable
memory
repeat
gard
if
necessary.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
72
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals