Table 5. Firmware Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
20A80002 Cannot get gateway IP address Refer to Table 3 on page 142 using
code E174.
20A80003 Cannot get server hardware address Refer to Table 3 on page 142 using
code E174.
20A80004 Bootp failed Refer to Table 3 on page 142 using
code E175.
20A80005 File transmission (TFTP) failed. Check network connection, try again.
20A80006 Boot image too large Contact your next level of support for
assistance.
20D00xxx Unknown/unrecognized device
20D0000F Self-test failed on device, no error
and/or location code information
available
Refer to note 5 on page 157 to see if a
location code is available for the device
the error was reported against.
1. Replace device indicated by the
location code (if available).
2. Go to “MAP 1540: Minimum
Configuration” on page 117.
20D00010 Self-test failed on device, cannot locate
package
Contact your service support
representative for assistance.
20D00011 Firmware RTAS attempt to allocate
memory failed.
Contact your next level of support for
assistance.
20E00xxx Security
20E00001 Privileged-access password entry error. The password has been entered
incorrectly. Retry installing the
password.
20E00004 Battery drained or needs replacement 1. Replace system rack operator panel
battery
Location: U1.1-P1-L1.
2. Replace system rack operator panel.
(See notes on page 157.)
3. Replace I/O planar in primary
drawer
Location: U0.1-P1.
20E00009 Invalid password entered - system
locked
The password has been entered
incorrectly three times.
Turn off, then turn on the system unit,
then enter the password correctly.
20EE0xxx Informational
20EE0003 IP parameter requires 3 dots ″.″ Enter valid IP parameter.
Example: 000.000.000.000
20EE0004 Invalid IP parameter Enter valid IP parameter.
Example: 000.000.000.000
Chapter 5. Error Code to FRU Index