Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
4B00F002 AIX terminated with fault information Review operator panel for fault
information.
Note any additional refcodes (see
Functions 11 to 19 - System Reference
Code on page 603 for location). For
each refcode, assemble a new SRC
and look up the action in the Chapter 5.
Error Code to FRU Index on page 157.
If the problem has not been resolved
after performing the action for a refcode,
try the next refcode. Proceed to MAP
1540: Minimum Configuration on
page 117 after all the actions for all the
refcodes have been performed.
4B00F003 AIX terminated with no fault information Review error logs, beginning with
service processor.
4B00F004 NVRAM corrupted Service processor card.
Location: U0.1-P1-X1
4B00F007 System power control network (SPCN)
fault
Review error logs, beginning with AIX.
4B00F008 Process runtime diagnostics (PRD) fault Review error logs, beginning with AIX.
4B00F00A PCI to ISA bridge fault
1. Service processor card.
Location: U0.1-P1-X1
2. Go to MAP 1540: Minimum
Configuration on page 117.
4B00F00B Super I/O fault Service processor card.
Location: U0.1-P1-X1
4B00F00C PCI to PCI bridge fault
1. I/O planar in primary drawer.
Location: U0.1-P1
2. Go to MAP 1540: Minimum
Configuration on page 117
4B00F00D Super I/O fault Service processor card.
Location: U0.1-P1-X1
4B00F00E Isolation processor fault 1. Service processor card.
Location: U0.1-P1-X1
2. I/O planar in primary drawer.
Location: U0.1-P1
176 Service Guide