Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
9032 SPCN communications failure, unit to rack.
The frame detected a BCC error on a
transmission from a secondary node to the frame.
The transmission is attempted again.
No action required. This reference code is logged
for error analysis only.
9033 SPCN communications failure, rack to unit.
A secondary node detected a BCC error on a
transmission from the frame. The transmission is
attempted again.
No action required. This reference code is logged
for error analysis only.
9034 Unsupported packet size.
The receiving node detected a packet exceeding
70 bytes. The frame can also return this code if a
secondary node returns more than 10 bytes to a
PAS command.
No action required. This reference code is logged
for error analysis only.
9035 Secondary SPCN node timeout.
A secondary SPCN node did not respond to a
command. The command was attempted again
and failed.
No action required. This reference code is logged
for error analysis only.
9036 Frame timeout.
One or more frames did not respond to a
command. The command is attempted again.
No action required. This reference code is logged
for error analysis only.
903B Invalid packet length for data sent.
The number of bytes sent or received does not
match the number of bytes specified in the
command.
No action required. This reference code is logged
for error analysis only.