Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
9024 SPCN firmware code not valid.
The firmware code in one of the secondary nodes
is not valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9025 SPCN firmware code is not valid.
The firmware code in one of the frames is not
valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9028 SPCN firmware code is not valid.
The firmware code in the primary node is not
valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9029 SPCN VPD damaged
The VPD record in the EEPROM has bad data.
Exchange the failing items for the node reporting
the failure.
SPCN card assembly, R21
Location: U1.1-P2-X1
902D Addressed frame is not in SPCN configuration
table.
The addressed frame is not in the SPCN
configuration table.
No action required. This reference code is logged
for information only.
9031 Frame-to-frame communications failure
The SPCN detected a BCC error on a
transmission from another frame. The
transmission is attempted again.
No action required. This reference code is logged
for error analysis only.