Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
90F1 A frame was added to the SPCN configuration.
No action required. This reference code is logged
for information only.
9101 Firmware-SPCN timeout.
A firmware timeout occurred. The SPCN failed to
respond to a firmware command.
1. ac box
Location: U1.2-V7
2. Operator panel assembly
Location: U1.1-P1-L1
9103 Download initialize timeout.
An SPCN node failed to enter the download state
after an initialize for download command.
Exchange the failing SPCN node.
SPCN card assembly, R21
Location: U1.1-P2-X1
9104 Download completion timeout.
An SPCN node failed to leave the download state.
Exchange the failing SPCN node.
SPCN card assembly, R21
Location: U1.1-P2-X1
9105 Load damaged timeout.
An SPCN node failed to enter the operational
state.
Exchange the failing SPCN node.
SPCN card assembly, R21
Location: U1.1-P2-X1
9106 An SPCN LID was not found.
No action required. This reference code is logged
for information only.
9107 An SPCN microcode download is required.
No action required. This reference code is logged
for error analysis only.
9108 A status change occurred in one of the SPCN
nodes.
No action required. This reference code is logged
for information only.
9109 Firmware code part number is not correct.
The AROS part number field was not updated to
the correct level after the system attempted to
load new firmware code.
SPCN card assembly, R21
Location: U1.1-P2-X1
9111 SPCN is too large for VLIC.
There are more nodes in the network than VLIC
can service.
SPCN code problem
1xxx
Chapter 5. Error Code to FRU Index 209