9112 Primary SPCN node is reporting load damaged.
The firmware code for the primary SPCN node is
damaged. The reload failed because the code
could not be found.
ac box
Location: U1.2-V7
9113 Secondary SPCN node is reporting load
damaged.
The firmware code for the secondary SPCN node
is damaged. The reload failed because the code
could not be found.
SPCN card assembly, R21
Location: U1.1-P2-X1
9114 Frame SPCN node is reporting load damaged.
The firmware code for a SPCN node is damaged.
The reload failed because the code could not be
found.
SPCN card assembly, R21
Location: U1.1-P2-X1
9115 SPCN command rejected by the service
processor.
The service processor rejected an SPCN
command from the firmware code.
No action required. This reference code is logged
for information only.
9116 SPCN - control panel interface failure.
The SPCN to control panel interface is not
working.
9117 SPCN - control panel interface is now working.
The SPCN to control panel interface is now
working.
No action required. This reference code is logged
for information only.
9212 Frame address field not valid.
A firmware code command had a frame address
that is not valid.
Exchange the failing items for the failing node.
SPCN card assembly, R21
Location: U1.1-P2-X1
9213 Invalid address status, secondary node.
The address in the SPCN command does not
match the assigned address of the secondary
node.
Exchange the failing items for the failing node.
SPCN card assembly, R21
Location: U1.1-P2-X1