Page #61 background imageLoading...
Page #61 background image
Table 6. IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3550 M3 Types 4254 and 7944,” on page 159 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The Processor CPU nStatus has Failed
with FRB1/BIST condition.
(n = microprocessor number)
Error A processor failed -
FRB1/BIST condition has
occurred.
1. Check for a server
firmware update.
Important: Some
cluster solutions
require specific code
levels or coordinated
code updates. If the
device is part of a
cluster solution, verify
that the latest level of
code is supported for
the cluster solution
before you update the
code.
2. Make sure that the
installed
microprocessors are
compatible with each
other (see “Installing a
microprocessor and
heat sink” on page 245
for information about
microprocessor
requirements).
3. (Trained service
technician only) Reseat
microprocessor n.
4. (Trained service
technician only)
Replace
microprocessor n.
(n = microprocessor
number)
Chapter 3. Diagnostics 43

Table of Contents

Other manuals for IBM System x3550 M3 Type 4254

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M3 Type 4254 and is the answer not in the manual?

IBM System x3550 M3 Type 4254 Specifications

General IconGeneral
ProcessorIntel Xeon 5600 series
Max Processors2
MemoryUp to 192 GB DDR3
Form Factor1U Rack
ChipsetIntel 5520
Drive BaysUp to 4 hot-swap 2.5-inch SAS/SATA or SSD
RAID SupportRAID 0, 1, 10
Network InterfaceDual-port Gigabit Ethernet
Power Supply460W or 675W
Expansion Slots2 PCIe 2.0
WeightApproximately 17.24 kg (38 lbs)
Memory Slots18 (RDIMM) or 12 (UDIMM)