4000008b-00000000 One or more of the Storage Management IP addresses has changed.
Explanation: This message is for the use case where an IP address for the Storage Management has changed
Severity: Info
Alert Category: System - IMM Network event
Serviceable: No
CIM Information: Prefix: IMM and ID: 0139
SNMP Trap ID: 37
Automatically notify Support: No
User response: Information only; no action is required.
80010002-2801ffff Numeric sensor [NumericSensorElementName] going low (lower non-critical) has asserted.
Explanation: The CMOS battery voltage has dropped below its specified threshold.
Severity: Warning
Alert Category: Warning - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0476
SNMP Trap ID: 13
Automatically notify Support: No
User response: Replace the CMOS battery.
80010202-0701ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: A Voltage has dropped below its specified threshold (sensor Planar 12V, Planar 3.3V, or Planar 5V).
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response:
v (Trained service technician only) If the specified sensor is Planar 3.3V or Planar 5V, replace the system board.
v If the specified sensor is Planar 12V, check the IMM event log for power-supply-related issues, and resolve those
issues. If the problem remains, (trained service technician only) replace the system board.