80010202-2801ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: The CMOS battery voltage has dropped below its specified threshold.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: Replace the CMOS battery.
80010204-1d01ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 1 (Fan 1A Tach or Fan 1B Tach) has gone low.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
v Reseat the failing fan indicated by the lit LED on the fan.
v Replace Fan.
80010204-1d02ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 2 (Fan 2A Tach or Fan 2B Tach) has gone low.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
v Reseat the failing fan indicated by the lit LED on the fan.
v Replace Fan.