EasyManua.ls Logo

Icom IC-M803

Icom IC-M803
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
CONNECTIONS AND INSTALLATION
9
9
AF/MOD Pin Pin name Description 
1 MOD+
Modulation input from an external
terminal unit.
Input impedance: More than 600 Ω
Input level: Approximately
0.77 V rms
2 MOD–
Coaxial ground for MOD+.
3 GND
Ground for digital equipment.
4 AF+
AF detector output for an external
terminal unit.
Output impedance: Less than 600 Ω
Output level: More than
770 mV rms
5 AF–
Coaxial ground for AF+.
6 GND
Ground for digital equipment.
7 NC
No connection.
8 SEND
Ground this pin to transmit. Ground level: –0.5 to 0.8 V
Input current: Less than 20 mA
9 GND
Ground for digital equipment.
REMOTE Pin Pin name Description
1 DCD Inputs terminal for carrier detection.
2
RXD Inputs terminal for receive data.
NMEA-OUT NMEA0183 ver 4.10 data output.
3
TXD Outputs transmit data.
NMEA-IN NMEA0183 ver 4.10 data input.
4 DTR Outputs data terminal ready signal.
5 GND Connected to ground.
6 DSR Inputs terminal for a data-set-ready signal.
7 RTS Outputs request-to-send data.
8 CTS Inputs terminal for clear-to-send data.
9 NC No connection.
GPS-DATA Pin Pin name Description
1
NMEA
+
NMEA0183 ver 4.10 data input
+
.
2
NMEA
_
Ground for NMEA data
+
.
15
69
15
69

Table of Contents

Other manuals for Icom IC-M803