Draco compact DVI KVM Extender
62 2021-07-09
8.2 Blank Screen
Diagnosis Possible Reason Measure
LED 3 off Power supply Check power supply units and
the connection to the power
network.
LED 1 on or
Connection between
Check interconnect cables and
CPU Unit:
LED 3 red or
yellow
No video signal detected
by source (computer,
CPU)
Check DVI-D cable to CPU
Download DDC information from
console monitors (see
Chapter 6.1, Page 43).
Reboot CPU if necessary.
CON Unit:
LED 3 red or
yellow
No monitor detected Check connection, length and
quality of the DVI-D cable to
monitor, tighten cable
thumbscrews.
No video signal detected
from CPU Unit
Check connection, length and
quality of interconnect cables
between the units.
Download DDC information from
console monitors (see
Chapter 6.1, Page 43).
Reboot CPU if necessary.
Pos: 77 /806-IHSE/ Hilfe im P roblemfall/ Störung am USB-HID-Anschluss/477-xx @ 5\mod_127893899 3948_6.doc @ 43307 @ 2 @ 1