EasyManuals Logo

Ihse Draco compact DVI 477 Series User Manual

Ihse Draco compact DVI 477 Series
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
Draco compact DVI KVM Extender
40 2021-07-09
5.5.1 Parameters for CPU Units
You can write the following parameters into the configuration file of a CPU
Unit.
DDC-Management
Parameter Function
ENAHPDET
Enable hotplug switch for K238-5x series
LOCKEDID Activate DDC write protection
Digital-Audio
Parameter Function
SRC32000 Activate sample rate conversion, sample rate
32 kHz (only with digital audio upgrade module)
SRC44100 Activate sample rate conversion, sample rate
44,1 kHz (only with digital audio upgrade
module)
SRC48000 Activate sample rate conversion, sample rate
48 kHz (only with digital audio upgrade module)
SRC96000 Activate sample rate conversion, sample rate
96 kHz (only with digital audio upgrade module)
SRC_NONE Deactivate sample rate conversion (only with
digital audio upgrade module)
Compression
Parameter Function
MEDCPRATE Activate medium compression rate
MINCPRATE Activate low compression rate
MAXCPRATE Activate high compression rate
ENADITHER Activate dithering filter for Mac OS systems

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ihse Draco compact DVI 477 Series and is the answer not in the manual?

Ihse Draco compact DVI 477 Series Specifications

General IconGeneral
BrandIhse
ModelDraco compact DVI 477 Series
CategoryExtender
LanguageEnglish

Related product manuals