MICRO S automatic Cutter motor
2. Pressurise the lifting bladder several
times with 6 bar and check the function
of the lifting links.
3. Then, under pressure, close the
compressed air control unit and check
whether the lifting bladder holds
pressure.
4. Put the radial bladder in a protective
tube and fill it with 2 bar compressed air,
close the compressed air control unit and
check whether the radial bladder holds
pressure.
5. Fill the axial muscle several times with
3.5 bar to control the exact movement.
6. Then close the compressed air control
unit under pressure and check whether
the pressure holds.
Caution
Inflation and testing of the radial bladder must
always be carried out in a suitable tube.
(DN 100)