Controller Status
Displays communication status between the PC and the iNetVu
®
Controller
Controller Normal
Indicates normal communication status between the Controller and the PC
Controller Failed
A failure in communication between the Controller and the PC has been
detected.
Motor Status
Displays the movement of the 3-axis motors: Elevation, Azimuth, and Polarization
EL Moving UP / DN
Elevation Motor is moving in the respective direction
(UP = Up, DN = Down)
AZ Moving Left / Right
Azimuth Motor is moving in the respective direction
PL Moving CCW / CW
Polarization Motor is moving in the respective direction
(CCW = Counter Clock-Wise, CW = Clock-Wise)
Motor Unknown
Motor Status cannot be detected.
Antenna Status
Displays any relevant information regarding the Limit Switches, Potentiometers and/or
Inclinometers.
Antenna Normal
Limit Switches are ON/OFF in the correct relation to the Elevation, Azimuth and
Polarization Angles.
Sensor Error
This status is an indication of problem with cabling or hardware and/or controller
setup. Stop and troubleshoot before proceeding.
Antenna Unknown
Mobile Platform cannot be found. Ensure that the iNetVu
®
Controller is
functioning and that all cables are connected should this indicator appear.