90 Intel
®
Modular Server System Service Guide
Storage Pool Details
The tabs displayed below the system graphic provide detailed information on the selected
storage pool. For a description of these tabs, refer to the following table.
Expand Storage Pool Allows the user to add one or more physical drives to an existing
storage pool to increase available space.
Prepare for Transport Prepares drives for removal from system.
Accept Incomplete State Enables an IT administrator to accept a condition where the storage
pool has fewer physical drives than it requires. The incomplete state
occurs when some but not all physical drives belonging to a storage
pool have been transported to a new system.
NOTE: Virtual drives in an incomplete storage pool can be
recovered by rebuilding the storage pool after you accept
the incomplete state only if the RAID level of the virtual drive
allows it to handle the loss of the number of drives that are
missing from the storage pool.
Start Rebuild This action is available if a physical drive in a storage pool has failed
and needs to be recovered by rebuilding with the hot-spare drive.
Table 12. Storage Pool Actions Menu
Global Action Menu Item Description