60 Intel
®
Modular Server System Service Guide
4. Install hard drives or hard drive filler panels, as necessary.
For instructions, see “Installing a 3.5-inch Hard Drive into the Storage Bay” on
page 46.
5. Install the I/O Cooling Module. You must ensure that the I/O Cooling Module being
installated is appropriate for the installed HDD Bay Module.
For information about choosing the appropriate cooling module, refer to the Intel
®
Modular Server Spare/Parts List and Configuration Guide. For instructions on installing
the I/O Cooling module, see “Installing the I/O Cooling Module” on page 39.
Replacing the Midplane
Removing the Midplane
To remove the midplane, follow these steps:
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. To avoid data corruption, ensure that drives in the HDD bay module are not online
and actively providing data storage to any of the installed compute modules.
3. Power down all installed compute modules.
4. Power down the Intel
®
Modular Server System MFSYS25/MFSYS35 by unplugging
power cords to all installed power supplies.
5. Remove the Compute Module(s) and/or filler panels.
For instructions, see “Removing an Intel® Compute Module” on page 53.
6. Remove the I/O Cooling Module.
For instructions, see “Removing the I/O Cooling Module” on page 38.
7. Remove all the installed hard drives and/or hard drive filler panels.
For instructions, see “Removing the 2.5-inch Hard Disk Drive Bay Module” on
page 54 or “Removing the 3.5-inch Hard Disk Drive Bay Module” on page 57.
8. Remove the Hard Disk Drive Bay Module.
For instructions, see “Removing the 2.5-inch Hard Disk Drive Bay Module” on
page 54 or “Removing the 3.5-inch Hard Disk Drive Bay Module” on page 57.
9. Remove the Main Cooling Modules.
For instructions, see “Removing a Main Cooling Module” on page 36.
10. Remove the Storage Control Module(s) and/or filler panels.
For instructions, see “Removing a Storage Control Module” on page 27.
11. Remove the Ethernet Switch Module(s) and/or filler panels.
For instructions, see “Removing an Ethernet Switch Module” on page 24.
12. Remove the Management Module.

Table of Contents

Other manuals for Intel MFSYS25V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel MFSYS25V2 and is the answer not in the manual?

Intel MFSYS25V2 Specifications

General IconGeneral
BrandIntel
ModelMFSYS25V2
CategoryServer
LanguageEnglish

Related product manuals