Intel® Server Board S1200V3RP TPS Appendix B: Integrated BMC Sensor Tables
Revision 1.2
223
Full Sensor
Name
(Sensor name
in SDR)
Se
ns
or
#
Platform
Applicabilit
y
Sensor
Type
Event/R
eading
Type
Event Offset Triggers
Contrib.
To
System
Status
Assert
/De-
assert
Reada
ble
Value/
Offset
s
Event
Data
Rearm
St
an
db
y
Sufficient resources.
Transition from
redundant
ed
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degrad
ed
05 - Non-redundant:
insufficient resources.
Non-
Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degrad
ed
SSB
Thermal Trip
(SSB Therm
Trip)
0
D
h
All
Temper
ature
01h
Digital
Discret
e
03h
01 State Asserted
Fatal
As
and
De
Trig
Offset
M
X
IO Module
Presence
(IO Mod
Presence)
0
E
h
Platform-
specific
Module
/Board
15h
Digital
Discret
e
08h
01 Inserted/Present
OK
As
and
De
Trig
Offset
M
-
SAS Module
Presence
(SAS Mod
Presence)
0
F
h
Platform-
specific
Module
/Board
15h
Digital
Discret
e
08h
01 Inserted/Present
OK
As
and
De
Trig
Offset
M
X
BMC
Firmware
Health
(BMC FW
Health)
10
h
All
Mgmt
Health
28h
Sensor
Specifi
c
6Fh
04 Sensor Failure
Degrad
ed
As
-
Trig
Offset
A
X
System
Airflow
(System
Airflow)
11
h
All
Other
Units
0Bh
Thresh
old
01h
Analo
g
FW Update
Status
12
h
All
Version
Change
2Bh
OEM
defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13
h
Platform-
specific
Module
/Board
15h
Digital
Discret
e
08h
01 Inserted/Present
OK
As
and
De
Trig
Offset
M
-
Baseboard
Temperature
5
(Platform
Specific)
14
h
Platform-
specific
Temper
ature
01h
Thresh
old
01h
[u,l] [c,nc]
nc =
Degrad
ed
c =
Non-
fatal
As
and
De
Analo
g
R, T
A
X

Table of Contents