Appendix B: Integrated BMC Sensor Tables Intel® Server Board S1200V3RP TPS
Revision 1.2
230
Full Sensor
Name
(Sensor name
in SDR)
Se
ns
or
#
Platform
Applicabilit
y
Sensor
Type
Event/R
eading
Type
Event Offset Triggers
Contrib.
To
System
Status
Assert
/De-
assert
Reada
ble
Value/
Offset
s
Event
Data
Rearm
St
an
db
y
MSID
Mismatch
(P1 MSID
Mismatch)
h
sor
07h
Discret
e
03h
and
De
Offset
Processor
Population
Fault
(CPU
Missing)
82
h
All
Proces
sor
07h
Digital
Discret
e
03h
01 State Asserted
Fatal
As
and
De
Trig
Offset
M
Processor 1
DTS
Thermal
Margin
(P1 DTS
Therm Mgn)
83
h
All
Temper
ature
01h
Thresh
old
01h
-
-
-
Analo
g
R, T
A
Processor 2
DTS
Thermal
Margin
(P2 DTS
Therm Mgn)
84
h
All
Temper
ature
01h
Thresh
old
01h
-
-
-
Analo
g
R, T
A
Processor 3
DTS
Thermal
Margin
(P3 DTS
Therm Mgn)
85
h
All
Temper
ature
01h
Thresh
old
01h
-
-
-
Analo
g
R, T
A
Processor 4
DTS
Thermal
Margin
(P4 DTS
Therm Mgn)
86
h
All
Temper
ature
01h
Thresh
old
01h
-
-
-
Analo
g
R, T
A
Processor2
MSID
Mismatch
(P2 MSID
Mismatch)
87
h
All
Proces
sor
07h
Digital
Discret
e
03h
01 State Asserted
fatal
As
and
De
Trig
Offset
M
Processor 1
VRD
Temperature
(P1 VRD
Hot)
90
h
All
Temper
ature
01h
Digital
Discret
e
05h
01 - Limit exceeded
Non-
fatal
As
and
De
Trig
Offset
M
Processor 2
VRD
Temperature
(P2 VRD
Hot)
91
h
All
Temper
ature
01h
Digital
Discret
e
05h
01 - Limit exceeded
Non-
fatal
As
and
De
Trig
Offset
M
Processor 3
92
All
Temper
Digital
01 - Limit exceeded
Fatal
As
Trig
M

Table of Contents

Other manuals for Intel S1200V3RP