75
Specification
9.2 Environmental Specication
Test Intellian Standard
Temperature (ADU)
Operational IEC-60945 (-25°C to +55°C / power on)
Survival
IEC-60945 (-40°C to +80°C / power on and a non-
functional state)
Storage IEC-60945 (-40°C to +85°C / power off)
Temperature (BDU)
Operational IEC-60945 (-25°C to +55°C / power on)
Survival
IEC-60945 (-40°C to +80°C / power on and a non-
functional state)
Storage IEC-60945 (-40°C to +85°C / power off)
Humidity IEC-60068-2-30
Vibration
Operational IEC-60945
Survival IEC-60721-3-6 Class 6M3
Shock
Operational IEC-60068-2-27
Survival (Transient) IEC-60721-3-6 Class 6M3
Survival (Bump) IEC-60721-3-6 Class 6M3
Salt Mist IEC-60068-2-52
Ingress Rating (ADU) IP56
Ingress Rating (BDU) IP31