RCA jack, 315mV, 600 ohms. Unbalanced 
Note: Line-level audio requires amplification. 
RS-485 port 
There is one RS-485 port on the back panel of the DVR to connect a PTZ dome 
camera or keypad. See Figure 3 for the serial pin outs. 
Figure 3: RS-485 pin outs 
 
 
D+: Connect to the RS-485 A connection on the 
dome camera or keypad. 
D-: Connect to the RS-485 B connection on the 
dome camera or keypad. 
 
RS-232 port  
Use the RS-232 port to connect CBR-PB3-POS (point-of-sale) and ATM devices 
to the DVR such as the UTC ProBridge accessory. See “Configuring the RS-232 
port” on page 99 for more information. 
PTZ dome camera set up 
Use the USB mouse provided or the optional keypad for local telemetry control. If 
using the DVR over a network, use the web browser to control the PTZ dome 
cameras or TruVision Navigator.  
See Appendix B on page125 for the supported protocols, and Appendix E on 
page 137 for the PTZ commands supported by each protocol.  
Each PTZ camera must be set up individually. For information on configuring 
PTZ dome camera settings, see Chapter 10, “Controlling a PTZ camera” on page 
73. 
Connecting a PTZ dome camera  
See Figure 4 below for how to connect a PTZ camera to the DVR. Any PTZ 
dome camera can be controlled as the DVR is doing the PTZ protocol translation.