Intermec EasyCoder C4 – Programmer’s Guide Ed. 3 16
Chapter 5 Editing in Form Edit Mode
Example, cont.
Command Explanation
↵ CR/LF to start command structure
FK"TEST" ↵ Delete any existing form named TEST
FS"TEST" ↵ Start store form named TEST
Defi ne Variables
The fi rst variable (V00) has a maximum size of 15 characters.
The second variable (V01) has 10 characters and prints in reverse.
The third variable (V02) has a maximum size of 8 characters.
Command Explanation
V00,15,N,"Enter Product name:" ↵ Defi ne fi rst variable
V01,10,L,"Enter Model number:" ↵ Defi ne second variable
V02,8,N,"Checked by:" ↵ Defi ne third variable
Name the Form
Name of this form is TEST.
The text within quotes are prompts, which will be sent from
the printer to the host when the label form is retrieved (serial
communication only).
Defi ne a Counter
The counter has maximum 6 digits.
Command Explanation
C0,6,L,+1,"Enter Serial Number:"↵ Defi ne counter
Note:
The variables (V00, V01, V02) and counter (C0), are defi ned
within this label form named TEST. The next label form containing
variables and counters, will again start with V00 and C0.
If variable data is being sent from an external data base, omit
the text between the quotes and replace with a space character,
for example
V00,15,N," "
.